1.
Gastroenterol Res Pract
; 2020: 9869742, 2020.
Article
in English
| MEDLINE | ID: covidwho-1021164
ABSTRACT
BACKGROUND: No consensus exists regarding which procedures should be performed to disinfect endoscopes and working platforms after COVID-19 patients have undergone endoscopy. METHODS: We analyzed the disinfection quality of endoscopes and working platforms after 11 COVID-19 patients had undergone endoscopy. CONCLUSIONS: For endoscopic preprocessing at the bedside, a key disinfection step is using a multienzyme stock solution. The nucleic acid tests for endoscopists, washers, endoscopes, and working platforms were all negative. Based on our experience with the 11 COVID-19 patients who had undergone endoscopy, we provide an endoscopic reprocessing method for the bedside endoscopic diagnosis and treatment of COVID-19 patients for reference.